2-2 Configuring TCP/IP
LX Series Configuration Guide
Configuring TCP/IP
You can let the LX unit obtain its TCP/IP parameters from the
network, or you can explicitly configure TCP/IP parameters for
the LX unit with the Quick Start Configurator or the
IP Configuration Menu. (You can access the IP Configuration
Menu from the ppciboot Main Menu.)
Obtaining TCP/IP Parameters from the Network
If the TCP/IP parameters for the LX unit have not been explicitly
configured, the LX unit will attempt to load its TCP/IP
parameters from the network when the LX unit boots. The LX
unit can load its TCP/IP parameters from any LAN that runs
DHCP, BOOTP, or RARP.
X To configure TCP/IP parameters with the
Quick Start Configurator
1. Plug in the terminal at the DIAG port (port 0) on the LX
unit. (The port values are 9600 bps, 8 bits, 1 stop bit, No
parity, and Xon/Xoff flow control.)
When the LX unit first boots up on default parameters, the
following message displays:
Run Initial Connectivity Setup? y/n
2. Press y (yes) and press Enter. The Enter your superuser
password message appears, followed by the Superuser
Password prompt.