5-18 syslogd Message Configuration Example
LX Series Configuration Guide
syslogd Message Configuration Example
This example shows how to change the text field, facility, and
priority of a configurable syslogd message.
X To access the Notification command mode
1. Execute the following commands:
Example
2. Change the text field of the message:
Example Notification:0 >>
message 1 string New CLI mode entered by
3. Change the priority setting of the message:
Example Notification:0 >>
message 1 priority notice
4. Change the facility setting of the message:
Example Notification:0 >>
message 1 facility daemon
Outbound Asynchronous Port Example
The following commands forwards the logging of events to
ports 5, 6, and 7:
Example
There are
no prereq-
uisites for
this task.
Login:
InReach
Password:
access
InReach:0>
enable
Password>>
system
InReach:0 >>
config
Config:0 >>
notification
Notification:0 >>
Notification:0 >>
profile service 3serialport
Noti_Serv_Protocol:0 >>
async
Noti_Serv_Async:0 >>
port 5 6 7
Noti_Serv_Async:0 >>
exit
Notification:0 >>
profile user serialport
Noti_User_Service:0 >>
service 3serialport
Noti_User_Info:0 >>
facility user
Noti_User_Info:0 >>
priority warning