System Administration
Upgrading Software and ppciboot using the Command-Line Interface 4-15
By default, the software stores in memory the IP address
of the TFTP/SFTP server from which it has booted. If your
file transfer protocol is TFTP, the “TFTP Download
complete, verifying file integrity” message
appears. If your file transfer protocol is SFTP, the “SFTP
Download complete, verifying file integrity”
message appears.
2. The loaded file is checked for integrity.
If the check is successful, following message displays:
File ok, copying image to flash
If the check finds a problem, the following message
displays:
Verify failed, Bad ppciboot file
3. You have upgraded ppciboot. You must reboot the unit for
the new ppciboot to take effect. Now you can upgrade the
software.
X To upgrade the software from the CLI
1. Type the following command and then press <Enter>:
Syntax InReach:0 >>update software [ipv6 <ipv6_address>]|
[<hostname_or_ip>] [image name <path/image_name>]
Example InReach:0 >>update software 1.2.3.4
2. Type the following command and then press <Enter> to
save your configuration locally, if desired:
Example InReach:0 >>save config flash
This stores the parameters.
3. Type the following command and then press <Enter> to
reboot the unit:
Example InReach:0 >>reload
When the reload is complete, log in again. The new
software is activated.