6-6 Specifying Socket Numbers
LX Series Configuration Guide
Specifying Socket Numbers
IP interfaces have a default SSH Socket Number of 22 and a
default Telnet Socket Number of 23. Table 6.2 lists the default
SSH and Telnet Socket Numbers for LX serial ports.
This section describes how to specify SSH Socket Numbers and
Telnet socket Numbers for IP interfaces and LX (asynchronous)
ports. This is typically done to prevent hackers from accessing
LX ports via default SSH Socket Numbers or default Telnet
Socket Numbers.
X To specify a Telnet socket number for a serial port
Execute the serial command with the telnet modifier.
In the following example, the Telnet Socket Number for serial
port 6 is set to 1297:
Example Intf 1-1:0 >>serial 6 telnet 1297
Table 6.2 Default Socket Numbers for Serial Ports
LX Serial Port Default Telnet Port Default SSH Port
00 0
1 2100 2122
2 2200 2222
3 2300 2322
4 2400 2422
5 2500 2522
6 2600 2622
7 2700 2722
8 2800 2822