14-6 OID Structure Example
LX Series Configuration Guide
Table 14.4 LX Enterprise-Specific SNMP Traps
ID
Name
Indicates that
1
irNotifyEvent A text message is being sent to an SNMP client.
2
irTempHighTholdAlarmRaised A configured high threshold has been raised.
3
irTempHighTholdAlarmCleared A configured high threshold has been cleared.
4
irTempLowTholdAlarmRaised A configured low threshold has been raised.
5
irTempLowTholdAlarmCleared A configured low threshold has been cleared.
6
irHumidityHighTholdAlarmRaised A configured high threshold was raised.
7
irHumidityHighTholdAlarmCleared A configured high threshold was cleared.
8
irHumidityLowTholdAlarmRaised A configured low threshold was raised.
9
irHumidityLowTholdAlarmCleared A configured low threshold was cleared.
10
irClusterSyncStarted A Cluster Synchronization started.
11
irClusterSyncCompleted A Cluster Synchronization completed.
12
irClusterSoftwareUpdateStarted A Cluster system software update started.
13
irClusterSoftwareUpdateCompleted A Cluster system software update completed.
14
irClusterBootloaderUpdateStarted A Cluster boot loader software update started.
15
irClusterBootloaderUpdateCompleted A Cluster boot loader software update completed.
16
irPowerSupplyStatusChanged A power supply status changed.
17
irLoginFailed A user tried to log in and failed.
18
irHdamAlarmRaised HDAM unit generated an alarm.
19
irHdamAlarmCleared HDAM unit cleared an alarm.
20
irHdamContactLost LX lost contact with the HDAM unit.
21
irHdamContactRegained LX regained contact with the HDAM unit.
22
irHdamPowerStatusChanged The HDAM power status has changed.
24
irOnBoardLowTempExceeded Onboard low temperature exceeded the threshold value.
25
irOnBoardLowTempCleared Onboard low temperature has fallen below the threshold
value.
26
irOnboardLowHighExceeded Onboard high temperature exceeds the threshold value.
27
irOnboardLowHighCleared Onboard high temperature has fallen below the threshold
value.