15-6 Enabling and Disabling Audible Alarms
LX Series Configuration Guide
2. Use the following command syntax to enable and disable
the audible alarm for multiple alarms:
Syntax hdam alarm <alarm_name> audible enable
hdam alarm <
alarm_name> no audible
where
Example
alarm_name Name of the alarm on which to enable/disable the
audible alarm. This entry is in the order port_slot_alarm
(such as 5_2_31, or BankVaultDoor).
enable Enables the audible alarm to sound when a fault
condition is detected on an Alarm Input of an LX-7204T/
7304T unit specified in alarm_name.
no audible Disables the audible alarm when a fault condition is
detected on an Alarm Input of an LX-7204T/7304T unit
specified in alarm_name (default).
port_number Specifies the HDAM port managing the LX-7204T/
7304T.
slot_list List of slots on which to enable the audible alarm. This
list can contain single items, lists (such as 1,3,4) or
ranges (such as 1-4).
point_list List of points on which to enable the audible alarm. This
list can contain single items, lists (such as 1,3,4) or
ranges (such as 1-32).
all Specifies that all Alarm Inputs managed by the LX
Master Unit will be as specified in this command.
Config:0 >>hdam alarm BankVaultDoor audible enable
Config:0 >>hdam alarm 5_2_31 no audible
Config:0 >>hdam alarm port 2 slot 1,2 point 1,2,3,4 no audible
Config:0 >>hdam alarm port 2 slot 1-4 point 6-18 no audible
Config:0 >>hdam alarm port 2 slot all point all audible enable
Config:0 >>hdam alarm port 2 slot 1-4 point 6-18 audible enable