14-16 Access
LX Series Configuration Guide
Access
This defines the abilities available to a GROUP that is bound to a
specific access entry. Access defines which VIEW from the VIEW
table is used to determine READ/WRITE capabilities.
View
This is where you limit what a user can view. You can specify a
certain OID; for example, 1.3.6.1. This means as long as the
user request attempts to read or write to a value that has
1.3.6.1 beginning the string, they will be able to do so.
Configuration
For SNMP V3 to function properly, an entry must exist in each of
the four tables. Your configuration is a logical linking of table
entries in the four different tables:
USER ---> GROUP---> ACCESS --->VIEW
The following sections consist of examples of how to configure
the SNMP V3 feature on the LX.
X To access SNMP commands
Execute the following commands in Configuration
Command Mode:
Config:0 >>snmp enable
Config:0 >>snmp
SNMP:0 >>