MRV Communications EM316-2SFP Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Vernetzung MRV Communications EM316-2SFP herunter. MRV Communications EM316-2SFP User's Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - EM316-2SFP

EM316-2SFP Transparent SFP-to-SFP Converter With EM316NM or EM316LNXNM-OT Management User Guide PN 1259003-001 Revision C3 October 30,

Seite 2 - Table of Contents

EM316-2SFP User Guide P/N 1259003-001 Rev C3 1 2 Product Overview The EM316-2SFP transparent converter contains two MSA compliant SFP socke

Seite 3

EM316-2SFP User Guide P/N 1259003-001 Rev C3 2 2.1.2 Loopback The EM316-2SFP module supports loopback either by DIP switch setting or co

Seite 4 - Table of Figures

EM316-2SFP User Guide P/N 1259003-001 Rev C3 3 3 Preparation and Installation 3.1 Unpacking the Fiber Driver Module Follow the steps below

Seite 5 - 1 Preliminary Considerations

EM316-2SFP User Guide P/N 1259003-001 Rev C3 4 3.2 Front Panel Description Figure 2 -- Front Panel Schematic of the EM316-2SFP The EM3

Seite 6

EM316-2SFP User Guide P/N 1259003-001 Rev C3 5 3.3 DIP Switch Configuration The EM316-2SFP factory default configuration is designed to oper

Seite 7 - 1.5 General Safety

EM316-2SFP User Guide P/N 1259003-001 Rev C3 6 3.4 Module Installation EM316xx cards are hot-swappable, and they are designed to insert int

Seite 8

EM316-2SFP User Guide P/N 1259003-001 Rev C3 7 Step 2. Install the module inside a Fiber Driver chassis by aligning the edge of the card wit

Seite 9

EM316-2SFP User Guide P/N 1259003-001 Rev C3 8 3.5 Small Form Pluggables (SFP): Handling and Installation The EM316-2SFP accepts any SFP that

Seite 10 - 2 Product Overview

EM316-2SFP User Guide P/N 1259003-001 Rev C3 9 3.5.2 Working with SFPs The pluggable optics modules used in the EM316xx products are extreme

Seite 11

EM316-2SFP User Guide P/N 1259003-001 Rev C3 10 3.5.2.2 Mylar Tab SFP Modules The Mylar tab or nail latch on the module has a tab that you m

Seite 12

EM316-2SFP User Guide P/N 1259003-001 Rev C3 i Table of Contents 1 Preliminary Considerations...

Seite 13 - 3.2 Front Panel Description

EM316-2SFP User Guide P/N 1259003-001 Rev C3 11 3.5.2.3 Actuator/Button SFP Modules The actuator/button SFP module has a button that you mus

Seite 14 - DIP Switch Settings

EM316-2SFP User Guide P/N 1259003-001 Rev C3 12 3.5.2.5 Bale Clasp SFP Module The bale clasp SFP module has a bale clasp that you use to sec

Seite 15 - Procedure

EM316-2SFP User Guide P/N 1259003-001 Rev C3 13 4 Module Management Most Fiber Driver modules, including the EM316-2SFP, may be managed b

Seite 16

EM316-2SFP User Guide P/N 1259003-001 Rev C3 14 4.1 Remote Command Line Interface (CLI) Setup The NM has at least one Ethernet port, which

Seite 17 - Fiber Inspection

EM316-2SFP User Guide P/N 1259003-001 Rev C3 15 4.3 EM316NM[-5] Command Line Interface (CLI) Command Line Interface (CLI) commands are us

Seite 18

EM316-2SFP User Guide P/N 1259003-001 Rev C3 16 EM316 (Chassis) Commands get-chassis-info arg1 Display chassis information [arg1] chassi

Seite 19

EM316-2SFP User Guide P/N 1259003-001 Rev C3 17 SFP Port Commands get-port-dd arg1 arg2 arg3 arg4 Get the port optics digital diagnostic in

Seite 20

EM316-2SFP User Guide P/N 1259003-001 Rev C3 18 4.4 EM316LNXNM-OT Command Line Interface (CLI) The EM316LNXNM-OT provides command line int

Seite 21

EM316-2SFP User Guide P/N 1259003-001 Rev C3 19 4.4.1 EM316LNXNM-OT Boot and CLI Login The box below shows the NM boot and login to the bui

Seite 22 - 4 Module Management

EM316-2SFP User Guide P/N 1259003-001 Rev C3 20 4.4.2 CLI Navigation The CLI uses five operational contexts: login, configuration, chassi

Seite 23

EM316-2SFP User Guide P/N 1259003-001 Rev C3 ii 4 Module Management ...

Seite 24

EM316-2SFP User Guide P/N 1259003-001 Rev C3 21 4.4.3 Login Context Commands and Examples The login context refers to the only CLI state n

Seite 25

EM316-2SFP User Guide P/N 1259003-001 Rev C3 22 4.4.3.3 “show running-config” The show running-config command displays the currently acti

Seite 26

EM316-2SFP User Guide P/N 1259003-001 Rev C3 23 4.4.3.4 “show startup-config” The show startup-config command displays the contents of th

Seite 27

EM316-2SFP User Guide P/N 1259003-001 Rev C3 24 4.4.4 Configuring System Parameters Enter "configuration" mode, as shown below,

Seite 28

EM316-2SFP User Guide P/N 1259003-001 Rev C3 25 4.4.5 Chassis Context 4.4.5.1 Chassis Context – “show” The following CLI excerpt shows a F

Seite 29

EM316-2SFP User Guide P/N 1259003-001 Rev C3 26 4.4.5.2 Displaying and Saving System Parameters Use the write terminal command to display

Seite 30 - 4.4.3.1 “show version”

EM316-2SFP User Guide P/N 1259003-001 Rev C3 27 4.4.5.3 Restoring Default Parameters Use the default command to discard changes applied t

Seite 31

EM316-2SFP User Guide P/N 1259003-001 Rev C3 28 4.4.5.4 Chassis Context – Other Commands The commands available at the chassis level are c

Seite 32

EM316-2SFP User Guide P/N 1259003-001 Rev C3 29 4.4.6 Slot Context Commands and Examples Command examples in this section are applied i

Seite 33

EM316-2SFP User Guide P/N 1259003-001 Rev C3 30 4.4.6.1 “?” The “?” is a special help character in the EM316LNXNM-OT command line. In previ

Seite 34

EM316-2SFP User Guide P/N 1259003-001 Rev C3 iii Table of Figures Figure 1 -- Unpacking ...

Seite 35

EM316-2SFP User Guide P/N 1259003-001 Rev C3 31 4.4.6.2 “list” The list command displays all the full command options (including applicabl

Seite 36

EM316-2SFP User Guide P/N 1259003-001 Rev C3 32 4.4.6.3 “show” The show command displays management and system information related to the

Seite 37

EM316-2SFP User Guide P/N 1259003-001 Rev C3 33 The boxes below illustrate two common parameters used with the show command. Default se

Seite 38

EM316-2SFP User Guide P/N 1259003-001 Rev C3 34 Each module may be given a descriptive name with the command below. The show command follow

Seite 39 - 4.4.6.1 “?”

EM316-2SFP User Guide P/N 1259003-001 Rev C3 35 4.4.7 Port Context Commands and Examples Command examples in this section are applied in

Seite 40 - 4.4.6.2 “list”

EM316-2SFP User Guide P/N 1259003-001 Rev C3 36 The box below shows the output of the “?” typed alone on the command line in the port-leve

Seite 41

EM316-2SFP User Guide P/N 1259003-001 Rev C3 37 4.4.7.2 “list” The list command displays all the full command options (including applicabl

Seite 42

EM316-2SFP User Guide P/N 1259003-001 Rev C3 38 4.4.7.3 “show” The show command displays management and system information related to the

Seite 43

EM316-2SFP User Guide P/N 1259003-001 Rev C3 39 4.4.7.4 Port Description fiberdriver(port/1.1.1)# description sfp-port1 fiberdriver(po

Seite 44 - 4.4.7.1 “?”

EM316-2SFP User Guide P/N 1259003-001 Rev C3 40 4.4.7.5 “show defaults” Default settings are listed in the show defaults command output. T

Seite 45

EM316-2SFP User Guide P/N 1259003-001 Rev C3 iv 1 Preliminary Considerations 1.1 Trademarks All trademarks are the property of their respe

Seite 46 - 4.4.7.2 “list”

EM316-2SFP User Guide P/N 1259003-001 Rev C3 41 4.4.7.7 Loopback Applying the “loopback” command to one port automatically adjusts the o

Seite 47

EM316-2SFP User Guide 4.4.7.9 Shutdown fiberdriver(port/1.2.1)# shutdown fdrd[60]|TRAP| err|Jul 07 21:36:13 Port 1.2.1 Amps Too L

Seite 48 - 4.4.7.4 Port Description

EM316-2SFP User Guide P/N 1259003-001 Rev C3 Appendix-43 5 Appendix 5.1 Technical Specifications Physical Dimensions 25 mm x 75 mm x 175

Seite 49 - 4.4.7.6 “show config”

EM316-2SFP User Guide P/N 1259003-001 Rev C3 Appendix-44 5.4 Troubleshooting This section provides basic troubleshooting to rectify the

Seite 50

EM316-2SFP User Guide P/N 1259003-001 Rev C3 Notes a

Seite 51

EM316-2SFP User Guide P/N 1259003-001 Rev C3 Notes b

Seite 52 - 5 Appendix

MRV Communications, Inc. 20415 Nordhoff Street Chatsworth, CA 91311 Tel: 818-773-0900 Fax: 818-773-0906 http://www.mrv.com

Seite 53 - 5.4 Troubleshooting

EM316-2SFP User Guide P/N 1259003-001 Rev C3 v 1.4 MRV Regulatory Compliance Contact your sales representative for more regulatory complian

Seite 54 - EM316-2SFP User Guide

EM316-2SFP User Guide P/N 1259003-001 Rev C3 vi 1.5 General Safety 1.5.1 Cautions and Warnings Disconnect all power from electronic devices

Seite 55

EM316-2SFP User Guide P/N 1259003-001 Rev C3 vii 1.5.3 Static Electricity Eliminate static electricity in the workplace by grounding oper

Seite 56

EM316-2SFP User Guide P/N 1259003-001 Rev C3 viii 1.6 Specific Document Information Document Number: P/N 1259003-001 Rev C3 Document:

Kommentare zu diesen Handbüchern

Keine Kommentare